Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 18.597
Filter
5.
Reumatol Clin (Engl Ed) ; 20(4): 181-186, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38614886

ABSTRACT

Temporal arteritis (TA) is the most common form of systemic vasculitis. Its diagnosis is based on criteria proposed by the American College of Rheumatology (1990), and its treatment is high-dose corticosteroids. Our objective is to assess the cost of diagnosing TA, and secondarily, cost-effective analysis of different diagnostic strategies (clinical, biopsy, doppler ultrasound) and therapeutic strategies (corticosteroid suspension). MATERIAL AND METHOD: Observational, retrospective study has been carried out on patients with AT (2012-2021). Demographic data, comorbidities, signs and symptoms suggestive of AT were collected. AT was diagnosed with a score ≥ 3 according to American College of Rheumatoloy criteria (ACR-SCORE). The costs of diagnosis and treatment modification were analysed. RESULTS: Seventy-five patients have been included, median age 77 (46-87) years. Headache, temporal pain and jaw claudication were significant for the diagnosis of TA. Patients with a halo on Doppler ultrasound and a positive biopsy have significantly elevated ESR and CRP compared to patients who do not. The cost of the AT diagnosis was 414.7 euros/patient. If we use ACR-SCORE ≥ 3-echodoppler it is 167.2 є/patient (savings 59.6%) and ACR-SCORE ≥ 3-biopsy 339.75 є/patient (savings 18%). If the corticosteroid was removed and a biopsy was performed, 21.6 є/patient (94.7% savings), if the corticosteroid was removed and Doppler ultrasound was performed, 10.6 є/patient (97.4% savings). CONCLUSIONS: Headache, temporary pain and jaw claudication are predictors of AT. Elevated ESR and CRP are predictors of positive biopsy and presence of halo on ultrasound. The uses of ACR-SCORE ≥ 3 with Doppler ultrasound or biopsy, and with corticosteroid suspension, are cost-effective.


Subject(s)
Cost-Benefit Analysis , Giant Cell Arteritis , Humans , Giant Cell Arteritis/diagnosis , Giant Cell Arteritis/economics , Retrospective Studies , Aged , Female , Male , Middle Aged , Aged, 80 and over , Ultrasonography, Doppler/economics , Biopsy/economics , Cost-Effectiveness Analysis
6.
Aging Male ; 27(1): 2339352, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38590113

ABSTRACT

OBJECTIVES: To evaluate the efficacy of a novel approach to achieve the optimal penile erection during the penile doppler ultrasound (PDU) examination, which was oral sildenafil combined alprostadil injection. MATERIALS AND METHODS: A total of 60 ED patients were enrolled in our prospective study, and they were randomly assigned to two group with different PDU order. The approaches assisted the PDU included two models, mode A meaning injection of 15 µg alprostadil and model B meaning oral sildenafil 100 mg plus injection of 15 µg alprostadil. The PDU parameters were measured continuously before induced erection, and 5, 10, 15, 20, 25 min. RESULTS: Each group included 30 ED patients with similar clinical characteristics. After pooling the results together, the PSV, EDV, and RI were all improved significantly, when adding the oral sildenafil administration to assist PDU. Also, the clinical response of oral sildenafil administration plus alprostadil injection was better than that in alprostadil injection alone (p = 0.016). The arterial ED were decreased from 31.67% to 15.00% with the P value 0.031, and the mixed ED was also decreased statistically (23.33% vs 8.33%, p = 0.024). CONCLUSION: Oral sildenafil administration plus alprostadil injection could improve the diagnostic accuracy of PDU.


Subject(s)
Erectile Dysfunction , Penile Erection , Male , Humans , Sildenafil Citrate/pharmacology , Penile Erection/physiology , Alprostadil , Erectile Dysfunction/drug therapy , Erectile Dysfunction/diagnosis , Prospective Studies , Penis/diagnostic imaging , Ultrasonography, Doppler
7.
Reumatol. clín. (Barc.) ; 20(4): 181-186, Abr. 2024. tab, ilus
Article in Spanish | IBECS | ID: ibc-232370

ABSTRACT

La arteritis de la temporal (AT) es la forma más frecuente de vasculitis sistémica, su diagnóstico está basado en criterios propuestos por el Colegio Americano de Reumatología (1990), y su tratamiento son corticoides a dosis elevadas. Nuestro objetivo es valorar el gasto del diagnóstico de la AT, y secundariamente análisis coste/efectivo de distintas estrategias diagnósticas (clínica, biopsia, eco-Doppler) y terapéuticas (suspensión del corticoide). Material y método: Estudio observacional, retrospectivo de pacientes con AT (2012-2021). Se recogieron datos demográficos, comorbilidades, signos y síntomas sugestivos de AT. Se diagnosticó AT con una puntuación ≥3 según los criterios del American College of Reumatology (ACR-SCORE). Se analizaron los gastos del diagnóstico y modificación de tratamiento. Resultados: Setenta y cinco pacientes, mediana edad 77 (6-87) años. Cefalea, dolor temporal y claudicación mandibular fueron significativos para el diagnóstico de AT. Los pacientes con halo en eco-Doppler y biopsia positiva, presentaron elevación de VSG y PCR de forma significativa en comparación con los pacientes que no. El gasto diagnóstico de AT fue de 414,7€/paciente. Si empleamos ACR-SCORE≥3-eco-Doppler serían 167,2€/paciente (ahorro del 59,6%) y ACR-SCORE≥3-biopsia 339,75€/paciente (ahorro del 18%). Si se retiraba corticoide y se realizaba biopsia hubiesen sido 21,6€/paciente (ahorro del 94,7%), si se retiraba corticoide y se realizaba eco-Doppler hubiesen sido 10,6€/paciente (ahorro del 97,4%). Conclusiones: Cefalea, dolor temporal y claudicación mandibular son predictores de AT. La elevación de VSG y PCR son predictores de biopsia positiva y presencia de halo en la ecografía.El empleo de ACR-SCORE≥3 con eco-Doppler o con biopsia, y con suspensión del corticoide son coste/efectivos.(AU)


Temporal arteritis (TA) is the most common form of systemic vasculitis. Its diagnosis is based on criteria proposed by the American College of Rheumatology (1990), and its treatment is high-dose corticosteroids. Our objective is to assess the cost of diagnosing TA, and secondarily, cost-effective analysis of different diagnostic strategies (clinical, biopsy, Doppler ultrasound) and therapeutic strategies (corticosteroid suspension).Material and method: Observational, retrospective study has been carried out on patients with TA (2012–2021). Demographic data, comorbidities, signs and symptoms suggestive of TA were collected. TA was diagnosed with a score ≥3 according to American College of Rheumatoloy criteria (ACR-SCORE). The costs of diagnosis and treatment modification were analysed. Results: Seventy-five patients have been included, median age 77 (46-87) years. Headache, temporal pain and jaw claudication were significant for the diagnosis of TA. Patients with a halo on Doppler ultrasound and a positive biopsy have significantly elevated ESR and CRP compared to patients who do not.: The cost of the TA diagnosis was 414.7 euros/patient. If we use ACR-SCORE≥3-echodoppler it is 167.2 €/patient (savings 59.6%) and ACR-SCORE≥3-biopsy 339.75 €/patient (savings 18%). If the corticosteroid was removed and a biopsy was performed, 21.6 €/patient (94.7% savings), if the corticosteroid was removed and Doppler ultrasound was performed, 10.6 €/patient (97.4% savings).Conclusions: Headache, temporary pain and jaw claudication are predictors of TA. Elevated ESR and CRP are predictors of positive biopsy and presence of halo on ultrasound. The uses of ACR-SCORE≥3 with Doppler ultrasound or biopsy, and with corticosteroid suspension, are cost-effective.(AU)


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Giant Cell Arteritis/diagnosis , Comorbidity , Ultrasonography, Doppler , Biopsy/classification , Rheumatology , Rheumatic Diseases , Retrospective Studies
9.
Sci Rep ; 14(1): 5919, 2024 03 11.
Article in English | MEDLINE | ID: mdl-38467666

ABSTRACT

The aim of this study was to investigate the pulmonary vasculature in baseline conditions and after maternal hyperoxygenation in growth restricted fetuses (FGR). A prospective cohort study of singleton pregnancies including 97 FGR and 111 normally grown fetuses was carried out. Ultrasound Doppler of the pulmonary vessels was obtained at 24-37 weeks of gestation and data were acquired before and after oxygen administration. After, Machine Learning (ML) and a computational model were used on the Doppler waveforms to classify individuals and estimate pulmonary vascular resistance (PVR). Our results showed lower mean velocity time integral (VTI) in the main pulmonary and intrapulmonary arteries in baseline conditions in FGR individuals. Delta changes of the main pulmonary artery VTI and intrapulmonary artery pulsatility index before and after hyperoxygenation were significantly greater in FGR when compared with controls. Also, ML identified two clusters: A (including 66% controls and 34% FGR) with similar Doppler traces over time and B (including 33% controls and 67% FGR) with changes after hyperoxygenation. The computational model estimated the ratio of PVR before and after maternal hyperoxygenation which was closer to 1 in cluster A (cluster A 0.98 ± 0.33 vs cluster B 0.78 ± 0.28, p = 0.0156). Doppler ultrasound allows the detection of significant changes in pulmonary vasculature in most FGR at baseline, and distinct responses to hyperoxygenation. Future studies are warranted to assess its potential applicability in the clinical management of FGR.


Subject(s)
Fetal Growth Retardation , Fetus , Pregnancy , Female , Humans , Fetal Growth Retardation/diagnostic imaging , Prospective Studies , Fetus/diagnostic imaging , Fetus/blood supply , Ultrasonography, Doppler , Computer Simulation , Ultrasonography, Prenatal/methods , Gestational Age
11.
Eur J Obstet Gynecol Reprod Biol ; 296: 316-320, 2024 May.
Article in English | MEDLINE | ID: mdl-38518486

ABSTRACT

PURPOSE: We aimed to investigate maternal thyroid parenchymal vascularity with 2-dimensional color superb microvascular imaging vascularization index (2D-cSMIVI) levels and thyroid gland volume in the first, second and third trimesters. METHODS: This longitudinal prospective study was carried out with participants selected from 30 healthy asymptomatic pregnant women. Ultrasonography (US) for the thyroid gland was performed in each trimester. The vascularization index (VI) values obtained by manually drawing the contours of the thyroid parenchyma in the longutidinal plane, using the free region of interest (ROI) with 2DcSMIVI mode. VI values obtained in each trimester, thyroid hormone levels (TSH, T3, T4) and thyroid volumes were compared. RESULTS: We have detected that thyroid gland vascularity increased significantly as pregnancy progresses. The mean VI values of thyroid gland in third trimester were significantly higher than first and second trimester (p < 0.001), and the mean VI values of the thyroid gland in the second trimester were significantly higher than first trimester (p < 0.001). During pregnancy, we detected the increase in VI values, TSH levels and thyroid gland volumes. CONCLUSION: Maternal thyroid gland gray scale findings, parenchymal vascularization, thyroid volumes should be evaluated routinely for the healthy fetal development. 2D-cSMIVI method allows us to evaluate vascularization with quantitative numerical values objectively. We have detected that the VI values and volume of the thyroid gland increases as pregnancy progresses. In the complex situation of pregnancy process, the thyroid gland can be evaluated quantitatively with SMI method effectively.


Subject(s)
Thyroid Gland , Ultrasonography, Doppler , Humans , Female , Pregnancy , Thyroid Gland/diagnostic imaging , Prospective Studies , Ultrasonography, Doppler/methods , Thyroid Hormones , Thyrotropin
12.
Actas urol. esp ; 48(2): 177-183, mar. 2024. tab, graf
Article in Spanish | IBECS | ID: ibc-231451

ABSTRACT

Introducción y objetivos La estenosis de la arteria del injerto renal (EAR) es una complicación vascular del trasplante renal cuya incidencia estimada es del 13%, la cual puede causar hipertensión arterial refractaria, disfunción renal y muerte prematura en los receptores. Métodos Se realizó un estudio retrospectivo que incluyó a todos los pacientes sometidos a trasplante renal entre 2014 y 2020. Los pacientes fueron evaluados mediante ecografía doppler renal sistemática tras el trasplante. Para identificar los factores de riesgo independientes de la estenosis de la arteria renal tras el trasplante, realizamos un análisis multivariante. Resultados Se incluyeron 724 trasplantes renales, el 12% eran de donante vivo y el 88% de donante fallecido. La edad media en los receptores era de 54,8 años y en los donantes era de 53. Se diagnosticó estenosis de la arteria del injerto renal en 70 (10%) receptores, la mayoría durante los primeros 6 meses después de la intervención. El 51% de los pacientes con estenosis de la arteria del injerto renal se manejaron de manera conservadora. El análisis multivariante mostró que la diabetes mellitus, el rechazo del injerto, la resutura arterial y el índice de masa corporal del donante eran factores de riesgo independientes de estenosis de la arteria renal después del trasplante. La supervivencia de los injertos con estenosis de la arteria del injerto renal fue del 98% a los 6 meses y del 95% a los 2 años. Conclusiones El uso sistemático de la ecografía doppler en el período inmediatamente posterior al trasplante permitió diagnosticar un 10% de estenosis de la arteria del injerto renal en nuestra cohorte. A pesar de los factores de riesgo mencionados anteriormente, un seguimiento y tratamiento adecuados podrían reducir el riesgo de pérdida del injerto en pacientes con estenosis de la arteria del injerto renal. (AU)


Introduction and objectives Transplant renal artery stenosis (TRAS) is a vascular complication after kidney transplantation which estimated incidence is 13%. It could cause refractory arterial hypertension, kidney dysfunction and premature death in transplant recipients. Methods We carried out a retrospective study including every patient who underwent renal transplantation between 2014 and 2020. They were evaluated with a systematic post-transplant renal Doppler ultrasound. To identify independent risk factors for transplant renal artery stenosis we performed a multivariate analysis. Results Seven hundred twenty-four kidney transplants were included, 12% were living donors and 88% were deceased donors. The mean age was 54.8 in recipients and 53 in donors. Transplant renal artery stenosis was diagnosed in 70 (10%) recipients, the majority in the first 6 months after surgery. The 51% of patients with transplant renal artery stenosis were managed conservatively. The multivariate analysis showed diabetes mellitus, graft rejection, arterial resuture and donor body mass index as independent risk factors for transplant renal artery stenosis. Survival of the grafts with transplant renal artery stenosis was 98% at 6 months and 95% at two years. Conclusions The systematic performance of Doppler ultrasound in the immediate post-transplant period diagnosed 10% of transplant renal artery stenosis in our cohort. Despite the above risk factors, an adequate monitoring and treatment could avoid the increased risk of graft loss in patients with transplant renal artery stenosis. (AU)


Subject(s)
Humans , Male , Female , Renal Artery Obstruction , Kidney Transplantation , Graft Survival , Ultrasonography, Doppler , Retrospective Studies
13.
Medicine (Baltimore) ; 103(10): e37372, 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38457566

ABSTRACT

This study aimed to investigate the value of placental real-time shear wave elastography combined with three-dimensional power Doppler index (3D-PDI) in the prediction of preeclampsia. We conducted a retrospective study selecting 60 pregnant women diagnosed with preeclampsia as the experimental group and 60 normal pregnant women as the control group from January 2021 to December 2022. The elastic modulus values of different regions of the placenta and placental 3D-PDI were detected and compared between the two groups. The ROC curve was used to evaluate the diagnostic value of each parameter, alone or in combination, for preeclampsia. The study findings demonstrated that the elastic modulus values of different regions of the placenta and 3D-PDI of the two groups have statistical significance. The values of SWE, VI, FI, and VFI are different in prediction of preeclampsia, and the combination of various parameters can improve the prediction value. Overall, our study provides a valuable method for the prediction of preeclampsia with the advantages of non-invasiveness, efficiency, and simplicity.


Subject(s)
Elasticity Imaging Techniques , Pre-Eclampsia , Pregnancy , Female , Humans , Placenta/diagnostic imaging , Pre-Eclampsia/diagnostic imaging , Retrospective Studies , Elasticity Imaging Techniques/methods , Ultrasonography, Prenatal/methods , Imaging, Three-Dimensional/methods , Ultrasonography, Doppler
15.
Comput Biol Med ; 171: 108033, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38430739

ABSTRACT

BACKGROUND AND OBJECTIVE: Atrioventricular valve disease is a common cause of heart failure, and successful surgical or interventional outcomes are crucial. Patient-specific fluid-structure interaction (FSI) modeling may provide valuable insights into valve dynamics and guidance of valve repair strategies. However, lack of validation has kept FSI modeling from clinical implementation. Therefore, this study aims to validate FSI simulations against in vitro benchmarking data, based on clinically relevant parameters for evaluating heart valve disease. METHODS: An FSI model that mimics the left heart was developed. The domain included a deformable mitral valve of different stiffnesses run with different inlet velocities. Five different cases were simulated and compared to in vitro data based on the pressure difference across the valve, the valve opening, and the velocity in the flow domain. RESULTS: The simulations underestimate the pressure difference across the valve by 6.8-14 % compared to catheter measurements. Evaluation of the valve opening showed an underprediction of 5.4-7.3 % when compared to cine MRI, 2D Echo, and 3D Echo data. Additionally, the simulated velocity through the valve showed a 7.9-8.4 % underprediction in relation to Doppler Echo measurements. Qualitative assessment of the velocity profile in the ventricle and the streamlines of the flow in the domain showed good agreement of the flow behavior. CONCLUSIONS: Parameters relevant to the diagnosis of heart valve disease estimated by FSI simulations showed good agreement when compared to in vitro benchmarking data, with differences small enough not to affect the grading of heart valve disease. The FSI model is thus deemed good enough for further development toward patient-specific cases.


Subject(s)
Heart Valve Diseases , Models, Cardiovascular , Humans , Patient-Specific Modeling , Ultrasonography, Doppler , Mitral Valve/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Hemodynamics/physiology , Computer Simulation
16.
Article in English | MEDLINE | ID: mdl-38319765

ABSTRACT

Ultrafast power Doppler imaging (uPDI) can significantly increase the sensitivity of resolving small vascular paths in ultrasound. While clutter filtering is a fundamental and essential method to realize uPDI, it commonly uses singular value decomposition (SVD) to suppress clutter signals and noise. However, current SVD-based clutter filters using two cutoffs cannot ensure sufficient separation of tissue, blood, and noise in uPDI. This article proposes a new competitive swarm-optimized SVD clutter filter to improve the quality of uPDI. Specifically, without using two cutoffs, such a new filter introduces competitive swarm optimization (CSO) to search for the counterparts of blood signals in each singular value. We validate the CSO-SVD clutter filter on public in vivo datasets. The experimental results demonstrate that our method can achieve higher contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and blood-to-clutter ratio (BCR) than the state-of-the-art SVD-based clutter filters, showing a better balance between suppressing clutter signals and preserving blood signals. Particularly, our CSO-SVD clutter filter improves CNR by 0.99 ± 0.08 dB, SNR by 0.79 ± 0.08 dB, and BCR by 1.95 ± 0.03 dB when comparing a spatial-similarity-based SVD clutter filter in the in vivo dataset of rat brain bolus.


Subject(s)
Signal Processing, Computer-Assisted , Ultrasonography, Doppler , Rats , Animals , Phantoms, Imaging , Blood Flow Velocity , Ultrasonography, Doppler/methods , Ultrasonography/methods
17.
PLoS One ; 19(2): e0298060, 2024.
Article in English | MEDLINE | ID: mdl-38359058

ABSTRACT

Fetal growth restriction (FGR) is one of the leading causes of perinatal morbidity and mortality. Many studies have reported an association between FGR and fetal Doppler indices focusing on umbilical artery (UA), middle cerebral artery (MCA), and ductus venosus (DV). The uteroplacental-fetal circulation which affects the fetal growth consists of not only UA, MCA, and DV, but also umbilical vein (UV), placenta and uterus itself. Nevertheless, there is a paucity of large-scale cohort studies that have assessed the association between UV, uterine wall, and placental thickness with perinatal outcomes in FGR, in conjunction with all components of the uteroplacental-fetal circulation. Therefore, this multicenter study will evaluate the association among UV absolute flow, placental thickness, and uterine wall thickness and adverse perinatal outcome in FGR fetuses. This multicenter retrospective cohort study will include singleton pregnant women who undergo at least one routine fetal ultrasound scan during routine antepartum care. Pregnant women with fetuses having structural or chromosomal abnormalities will be excluded. The U-AID indices (UtA, UA, MCA, and UV flow, placental and uterine wall thickness, and estimated fetal body weight) will be measured during each trimester of pregnancy. The study population will be divided into two groups: (1) FGR group (pregnant women with FGR fetuses) and (2) control group (those with normal growth fetus). We will assess the association between U-AID indices and adverse perinatal outcomes in the FGR group and the difference in U-AID indices between the two groups.


Subject(s)
Fetus , Placenta , Female , Humans , Pregnancy , Biometry , Cohort Studies , Fetal Development , Fetal Growth Retardation/diagnostic imaging , Fetal Growth Retardation/epidemiology , Fetus/diagnostic imaging , Fetus/blood supply , Gestational Age , Multicenter Studies as Topic , Placenta/diagnostic imaging , Retrospective Studies , Ultrasonography, Doppler , Ultrasonography, Prenatal/methods , Umbilical Arteries/diagnostic imaging
18.
J Feline Med Surg ; 26(2): 1098612X231216350, 2024 02.
Article in English | MEDLINE | ID: mdl-38381465

ABSTRACT

OBJECTIVES: A comparative assessment of systolic blood pressure (BP) measurement agreement and precision in two commonly used non-invasive BP devices was carried out in conscious cats. METHODS: Systolic BP measurements were obtained from 50 conscious cats as part of their clinical investigations. All measurements were taken by the same operator and were performed according to the American College of Veterinary Internal Medicine (ACVIM) consensus guidelines. The same cuff location and cuff size were used for paired measurements. The order of device use was randomised, and an arousal score was assigned during each procedure. Precision was assessed using standard deviation and coefficient of variance comparisons. Agreement was assessed using graphical and statistical comparisons of derived 'delta mean' and 'mean of means' data. RESULTS: A total of 50 cats aged between 3 months and 15 years were enrolled (29 domestic shorthair, seven domestic longhair, three British Shorthair, two Ragdoll, two Sphynx, two Persian, one Siamese, one Burmese, one Russian Blue, one Maine Coon and one Oriental) with a body weight in the range of 1.2-6.2 kg. BP measurements were in the range of 95-179 mmHg. Oscillometric measurements were associated with lower arousal scores. The Doppler device demonstrated superior repeatability precision. Body weight, sex, cuff size, cuff location, arousal score and the order in which the devices were used had no significant effect on precision or agreement. Correlation between the two devices was 0.0837 and agreement was considered clinically acceptable (<10 mmHg) in 32/50 (64%) cats. Of the 18 cats with suboptimal agreement, the oscillometric mean BP was higher in 14 (78%) cats. CONCLUSIONS AND RELEVANCE: Based on this study sample, suboptimal agreement between paired CAT+ Doppler and SunTech Vet20 oscillometric BP measurements in 36% of conscious cats suggests that these devices should not be used interchangeably. Compared with Doppler, oscillometric measurements were consistently higher, particularly at higher blood pressures. Further studies are required to assess which device has superior accuracy in conscious cats.


Subject(s)
Cat Diseases , Hypertension , Humans , Cats , Animals , Blood Pressure , Ultrasonography, Doppler/veterinary , Hypertension/veterinary , Body Weight , Consciousness
20.
ARP Rheumatol ; 3(1): 29-39, 2024.
Article in English | MEDLINE | ID: mdl-38368555

ABSTRACT

INTRODUCTION: Psoriasis is a widespread chronic inflammatory skin disease; enthesitis is inflammation of the tendon, ligament, and joint capsule insertion, prevalent in patients with psoriatic arthritis. OBJECTIVES: The aim of study to evaluate the utility of the Madrid Sonography Enthesitis Index scoring system for accurate detection of subclinical enthesitis in patients with Psoriasis compared with healthy controls. Another objective was to assess increase in enthesis area and Psoriatic arthritis incidence, in a prospective 1-year follow-up. METHOD: Patients aged ≥18 years who were diagnosed with Psoriasis, without musculoskeletal complaints, and who did not have any clinical sign and/or symptom of enthesitis and synovitis were included in the study. The patients and healthy controls were evaluated with ultrasonography. Ultrasonography evaluation consisted of the detection of gray-scale enthesitis and power Doppler signal in the enthesis areas. The Madrid Sonography Enthesitis Index scoring system was used to quantify the extent of the sonographic enthesis abnormalities. RESULTS: The mean MASEI score, structure, thickness, erosion, and calcification were significantly higher in the Psoriasis group than in the control group. The mean MASEI score, structure, erosion, and calcification measurements were significantly higher at the last examination when compared to the first examination. The triceps was the most commonly affected tendon in both groups. CONCLUSION: Ultrasonography is an important tool for diagnosis and follow-up of subclinical enthesitis in patients with psoriasis. Regardless of disease duration and severity, patients should be screened using ultrasonography at yearly intervals.


Subject(s)
Arthritis, Psoriatic , Calcinosis , Enthesopathy , Psoriasis , Humans , Adolescent , Adult , Arthritis, Psoriatic/complications , Prospective Studies , Psoriasis/complications , Ultrasonography , Ultrasonography, Doppler , Enthesopathy/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...